FLUKE 17B Digital Multimeter
General Specifications:
Maximum Voltage between any Terminal and Earth Ground: 1000 V
Fuse Protection for mA μA inputs: 500 mA, 1000 V FAST, Min. Interrupt Rating 20,000 A
Fuse Protection for A input: 10 A, 1000 V FAST, Min. Interrupt Rating 20,000 A
Display: Digital: 4000 count updates 3/sec
Temperature: Operating: 0 °C to 40 °C, Storage: -30 °C to 60 °C indefinitely (to -40 °C for 100 hours)
Operating Altitude: 0 to 2000 meters
Temperature Coefficient: 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Electromagnetic Compatibility: Complies with FCC Part 15, Class B, IEC 61326, 3 V/m, performance criterion B
Rated Transient Over-voltage: 4 kV (1.2 x 50 μs) Peak for measurement Categories I, II, and III.
Relative Humidity: Non-condensing < 10 °C; 90% from 10 °C to 30 °C; 75% from 30 °C to 40 °C
Relative Humidity, 40 MΩ Range: 80% from 10 °C to 30 °C; 70% from 30 °C to 40 °C
Battery Type: 2 X AA, NEDA 15A, IEC LR6
Battery Life: Alkaline: 500 Hours
Size (H x W x L): 7 " X 3.5" X 2" (with holster)
Weight: 15 once (less than 1 LB)
Certifications: CMC,
Safety Compliance: IEC 61010-1, 2000 CAT I 1000 V, CAT II 600 V, and CAT III 300 V over voltage standards
Over-voltage installation categories per IEC 61010-1, 2000: The Meter is designed to protect against transients in these categories:
CAT I: From high-voltage low-energy sources, e.g., electronic circuits or a copy machine.
CAT II: From equipment supplied from the fixed installation, e.g., Televisions, PCs, portable tools and
household appliances.
CAT III: From equipment in fixed equipment installations, e.g., installation panels, feeders and short
branch circuits, and lighting systems in large buildings.
Accuracy Specifications Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Function |
Range |
Resolution |
Accuracy |
|
Model 15B |
Model 17B |
|||
AC Volts (40 to 500 Hz) v |
400.0 mV 1 |
0.1 mV |
3.0 % + 3 |
3.0 % + 3 |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V 001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 |
1.0 % + 3 |
|
DC Millivolts M |
400.0 mV |
0.1 mV |
1.0 % + 10 |
1.0 % + 10 |
DC Volts V |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V 001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 |
0.5 % + 3 |
Diode Test |
1.000 V |
0.001 V |
10 % |
|
Temperature 3 °C (K-type thermocouple) |
50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C |
0.1 °C |
NA |
2 % + 1 °C ± 2 °C 9 % + 2 °C |
Resistance (Ohms) |
400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ |
0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
Capacitance 4 c |
50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF |
0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA |
0.1 % + 3 |
Duty Cycle |
0.1 % to 99.9 % |
0.1% |
NA |
1% typical 5 |
1. Manual and Auto Range. 2. Diode test open circuit test voltage is 1.1 V to 1.6 V and short circuit current is < 0.6 mA (typical). 3. Temperature specifications do not include thermocouple errors. After inserting the thermocouple plug into the meter, allow several minutes for thermal stabilization. 4. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). For the 17B, errors can be reduced by using the relative feature. 5. For values between 10% and 90% duty cycle at 50 Hz. |
Function |
Range |
Resolution |
Accuracy |
||
Model 15B |
Model 17B |
||||
AC Current (40 to 200 Hz) |
400.0 µA |
0.1 µA |
1.5 % + 3 |
1.5 % + 3 |
|
|
4000 µA |
1 µA |
|
|
|
AC Current (40 to 200 Hz) |
40.00 mA |
0.01 mA |
1.5 % + 3 |
1.5 % + 3 |
|
|
400.0 mA |
0.1 mA |
|
|
|
AC Current (40 to 200 Hz) |
4.000 A6 10.00 A |
0.01 A 0.01 A |
1.5 % + 3 |
1.5 % + 3 |
|
DC Current |
400.0 µA |
0.1 µA |
1.5 % + 3 |
1.5 % + 3 |
|
|
4000 µA |
1 µA |
|
|
|
DC Current |
40.00 mA |
0.01 mA |
1.5 % + 3 |
1.5 % + 3 |
|
|
400.0 mA |
0.1 mA |
|
|
|
|
|
|
|
|
|
DC Current |
4.000 A6 |
0.01 A |
1.5 % + 3 |
1.5 % + 3 |
|
|
10.00 A |
0.01 A |
|
|
|
6. When in the 4A range, display will show 4000 counts, please ignore the last digit. |
|
||||
Function |
Overload Protection |
Input Impedance (Nominal) |
Common Mode Rejection Ratio |
Normal Mode Rejection |
AC Volts v |
1000 V |
>10 MΩ <100 pF |
>60 dB at dc, 50 or 60 Hz |
_ |
DC Volts V |
1000 V |
>10 MΩ <100 pF |
>100 dB at dc, 50 or 60 Hz |
>45 dB at 50 or 60 Hz |
106 V Hz Max |
|
|
|
|